Changes of the format settings for the date and time format master are not reflected.

 
This is a bug in the intra-mart Accel Platform product.
This event occurs in the intra-mart Accel Platform 2014 Spring (Granada) to 2015 Winter (Lydia) version.

▪Contents of the bug
Date and time formats are determined in the following order:
1. Settings selected by a logged-in user in the "Date and time format" of the personal settings
2. Settings selected by a tenant administrator in the "Date and time format" of the tenant management function
3. Settings of the date and time format master
If you have not set the settings of 1. and 2., 3. should be used. But after intra-mart Accel Platform 2014 Spring (Granada), even if the settings 3 is changed, it will still refer to the previous information.
This is because 3. is set as default for 2. when the tenant is created.
Therefore, even if you change the settings 3 after the start of operation, the information of when you created the tenant will be used.

▪Handling methods
For items of 2. that can be set, please deal with the problem by setting it for each tenant.
For the following format IDs, it is not possible to set it in the tenant management function, so it is still necessary to delete the corresponding information in the database.
If you want to change the date and time display format after the start of operation, correct the corresponding data in the "Im_tenant_dtf" table directly.
[Corresponding format IDs]
- IM_DATETIME_FORMAT_DATE_INPUT
- IM_DATETIME_FORMAT_TIME_INPUT
The information is stored in the system database and cannot be operated from the intra-mart Accel Platform screen.
Use the tools in your DBMS to remove the following information.
·Table name: im_tenant_dtf
·Target record: Record that matches the following (there should be the same number of them as the number of locales in your environment.)

·tenant_id - a tenant ID of the target
·format_id = IM_DATETIME_FORMAT_DATE_INPUT and IM_DATETIME_FORMAT_TIME_INPUT

If you deleted format_id other than the above, the settings of 2. will be deleted.
In that case, please set it up with the tenant administrator again.
From intra-mart Accel Platform 2016 Spring (Maxima), it is now possible to change the date and time display format of input from the screen.
For more information on changing the date and time format of the input, please refer to the following document.
·System administrator operation guide https://www.intramart.jp/document/library/iap/public/operation/system_administrator_guide/texts/tenant/setting_to_tenant_env.html
·Tenant administrator operation guide https://www.intramart.jp/document/library/iap/public/operation/tenant_administrator_guide/texts/basic_guide/basic_guide_7.html

-- Target -----------------------------------------------------------------------
iAP/Accel Platform/2014 Spring (Granada)
iAP/Accel Platform/2014 Summer (Honoka)
iAP/Accel Platform/2014 Winter (Iceberg)
iAP/Accel Platform/2015 Spring (Juno)
iAP/Accel Platform/2015 Summer (Karen)
iAP/Accel Platform/2015 Winter (Lydia)
---------------------------------------------------------------------------------


FAQID:484
Was this article helpful?
0 out of 0 found this helpful
Powered by Zendesk